TECO TK 5K - Hydroponic heat pump - cooling + heating
Code: 27426/CHL2Related products
Product detailed description
The TECO TK-series Heat Pumps are high-performance units designed for aquarium applications. These heat pumps are built with high-quality materials, even the smallest components.
HIGH-PERFORMANCE REFRIGERATION TECHNOLOGY
TK Heat Pumps use internationally-recognized rotary compressors with a titanium coaxial heat exchangers to ensure low-energy consumption while sustaining the highest in performance throughput. The technology in these heat pumps allows one to decrease noise levels and achieve a high COP (coefficient of performance) contributing to significant energy savings.
DIGITAL THERMOSTAT
The setting of functions is intuitive and the temperature detection is accurate, resolution 0.5°C/1°F. The setting range is 5°-40°C (41°F-104°F) and there is a closed loop temperature control system with high accuracy and extremely tight differential 2°C/5°F. Displayed temperature is in °C or °F and there are security alarms. Possibility to control remotely the display using supplied cable, degree of protection IPX4.
EFFICIENT DESIGN
The unit is characterized by a solid structure and was designed to provide maximum oxidation protection--great for use with salt-water.
UNIQUE FEATURES
TK Heat Pumps are also suitable for many industrial applications.
SPECIFICATIONS:
Aquarium Size | please contact us for specific sizing |
Horsepower | 2 HP |
Maximum Pressure | 29 psi |
Minimum Flow Rate | 3000l/h |
Maximum Flow Rate | 5000l/h |
In/Out Water Connection | 1.5" tube diameter |
Supply | 240-volts, 60Hz - 1 phase/6.7 Amps |
Gas/Refrigerant | R410A |
Cooling Power | 5.8 kW |
Required Breaker | 40 Amp |
Cooling Power Consumption | 2030 Watts - 6930 BTU/hr |
Heating Power Consumption | 1500 Watts - 5120 BTU/hr |
Working Modes | Cool, Heat |
Weight | 174.17 lbs ( 79 kg) |
Dimensions | 66,5 x 72,5 x 82,7 cm |
Note for first-time users:
If you should have problems with your chiller please contact us before returning the chiller to us. In most cases there is no actual problem with the chiller, but the functionality of the unit is not fully understood by the user yet. Please note the following: The compressor unit automatically switches itself on and off, if the temperature sensor is manipulated your warranty is void, the noise level or an allegedly not sufficient cooling performance are no reason for a reclamation. The chiller can only function properly if the cooling loop is equipped with a sufficiently powerful pump. If these facts are considered most reclamations can be avoided and you will greatly enjoy this product!