Product detailed description

The ballast offers 4 different output powers: 250W, 400W, 600W and Boost (660W).
Compared to older magnetic ballasts, it is much safer, does not heat up, is quiet and also much more efficient in electricity consumption. energy.
It is equipped with a 2m long power cable to the network and an IEC connector at the output to the shade.

  

1.Size

1.1 Rectifier Length(L) [mm] 270± 2

1.2 Rectifier Width(W) [mm] 100± 2

1.3 Rectifier Heigth(H) [mm] 60± 2

2.Data of Ballast

2.1 Starting voltage min. [V] 180 Vac

2.2 Starting time [S] 5Max

2.3 Pulse voltage [KV] 3-4.5kv

3.Lamp electrical parameter

3.1 Lamp type MH/HPS600W

3.2 Lamp voltage [V] 120(HPS)

3.3 Lamp current [A] 5

3.4 Lamp wattage [W] 600

  1. Input parameter

4.1 Input voltage [ V] 230 Vac

4.2 Current reference [A] 3(super)

4.3 Input wattage [W] 680((super)

4.4 Input frequency [HZ] 50/60

4.5 Power factor [ cos

 

Φ] ≥0.98

4.6 THD / ≤10

5.Output parameter

5.1 Output frequency [kHz] 70-210

5.2 The dimming range 4(250,400,600,super)

5.3 Open circuit voltage [V] ≤400

5.4 Crest factor ≤1.7

5.5 Factor ≥94.5%

  1. Other

6.1 Surface temperature [℃] 70Max.

6.2 Ambient temperature [C°] -20-30

 

WARNING

  1. Ensure the power shut down before check, install or replace the bulb.
  2. Keep away from the liquid.
  3. Keep away from inflammable and explosive materials.
  4. Not more than the rated voltage.
  5. Pls in the period of validity.
  6. Ground connection and Do a good job in ventilation and heat dissipation.
  7. Using the match lamp bulb.
  8. Check the input and output right.
  9. Turn the light after checking everything above are ok.

 

CAUTION

  1. Do all operations after cooled completely.
  2. Electric capacity inside, do not open the housing of the ballast immediately, avoid

burning your skin.

  1. Please use the professional tools.

 

NOTICE

  1. If the ballast stops working due to the triggering of the thermal protection, restart

the ballast after waiting 1 minute.

  1. Switch off the ballast's power supply before Replacing the lamp.
  2. Restart the ballast after waiting for more than 8 minutes.

Additional parameters